C196-E027A SCL-10AVP System Controller for Shimadzu VP Series HPLC System Command all VP Series components centrally with Shimadzu’s SCL-10AVP System Controller. The SCL-10AVP conveniently links all VP Series modules via fiber optic interfacing for easy “plug-andplay” setup, and is backward compatible with previous Shimadzu systems. Single point control allows user-friendly operation from the controller’s easy-to-read, menu-driven display screens. For unmatched control capability, pair the SCL-10AVP with Shimadzu’s powerful CLASS-VP™ chromatography software. GLP/GMP compliance Built-in validation support functions help you comply with GLP/GMP regulations. A record of each module’s operation is preserved and can be reviewed on-screen. Transfer and store methods Save method parameters to the built-in 3.5” disk drive for reference and for secure transfer to other VP Series HPLC Systems. ROM version updates are downloaded from disk for easy upgradeability. User-friendly interface Large, easy-to-read characters, icons and user-selectable display menus simplify system operation for novice and advanced users. Flow rates, gradient programs, chromatograms, and wavelength scan data (from the SPD-10AVP and 10AVVP) are displayed on-screen for easy graphical parameter determination and setup. The VP Series Means Validation and Productivity SCL-10AVP System Controller Advanced operation Function keys and detailed help information (with valid parameter ranges) streamline parameter setup and instrument operation. Time programs are easily created for precise component control. The graphical user interface rapidly creates and edits gradient curves for VP Series solvent delivery units (LC-10ADVP and 10ATVP). Simple mode for routine analyses Operate your isocratic system with a simplified parameter setup. Enter pump flow rate, detector wavelength, column oven temperature and autoinjector batch schedule parameters. Advanced mode for full control The SCL-10AVP’s advanced mode accesses full VP Series capability. All operational parameters are controlled by the SCL-10AVP. For autoinjector pretreatment programming, select either simple mode (Quick-pret) or full mode (Pret-prog). Custom display For fast, easy operation, tailor the menu options to your requirements. The VP Series Means Validation and Productivity Display Large backlit LCD display with easy-to-read characters and icons Status Indicators Indicate operational modes and status Operation Keypad For entering parameter values Function Keys Access the functions of individual screens Floppy Disk Drive For method storage and secure transfer to other VP Series HPLC Systems Advanced fiber optic communication Each component of the LC-10AVP Series is connected to the system controller by fiber optic interface. This low noise, highspeed mode of data transmission enhances the reliability and sensitivity of the HPLC system. An optional SCSI interface allows multiple VP Series HPLC Systems to be linked. CLASS-VP™ workstation interface Digital signals from VP Series detectors are rapidly transmitted from the SCL-10AVP to the CLASS-VP Chromatography Workstation by standard RS-232C interface. Analog signals from other manufacturers’ detectors can be converted to digital by the SCL-10AVP (option). The VP Series Means Validation and Productivity Specifications: SCL-10AVP (Cat. No. 228-34350-xx) Display Floppy Disk Drive Input/Output Terminals Possible Component Connection (Parameter setting files) Analysis file Time program Fraction collector file Time program Backlit LCD display (320 × 240 dots) Double sided high density track, Disk: 2HD External start input (MAN. INJ. in): 1 Error input (ALARM IN): 3 Output (EVENT1,2,3,4): 4 External power switch control (AC REMOTE): 1 Optical Link (OPT LINK): 1 (for Chromatopac) RS-232C: 1 (for PC) Remote Signal: 8 (for LC-10AVP/10A module control) Solvent delivery unit: max. 3 Autoinjector: 1 Column Oven: 1 Detectors: max. 2 Fraction Collector: 1 Sub-controller or valve interface: 1 2 or 6 position valve: 2 (via Sub-controller or valve interface) Solenoid valve unit: 1 (via Sub-controller or solvent delivery unit) He degassing unit: (via Sub-controller or solvent delivery unit) 20 files (parameters, time programs) Total 400 steps, 0.01∼9999.9 min, 10 files (parameters, time programs) Total 100 steps, 0.33∼9999.9 min, Autoinjector sequence file 102 steps or analysis sequence file 20 files, 250 byte/file Autoinjector Sample Pretreatment file (Solvent delivery unit control) Isocratic, High pressure gradient, Low Control mode pressure gradient, Constant pressure delivery Flow rate, Pressure, Concentration, Max. Selectable parameters pressure, Min. pressure, Linear, Step, Gradient profile Exponential function (all multi-level) (Autoinjector control) Sample injection volume, No. of repetitions of analyses, Analysis time or analysis file No., Sample Selectable Parameters pretreatment file No., Fraction collector file No. (Column oven control) Oven temperature Maximum temperature Selectable Parameters (Detector control) Detection wavelength, Range, Time constant, Lamp switching, Wavelength scanning conditions, etc. Selectable Parameters (Fraction collector control) Scan parameters, Peak detection parameters, Analytical conditions, etc. Selectable Parameters Memory check, Max./Min. Pressure limits, Self diagnostics, Oven temperature upper limit, Lamp current, Safety features Motor rotation, etc., abnormality check 260W × 420D × 140H㎜, approx. 6㎏ Dimensions, weight Ambient temperature range 4∼35℃ 228-34350-91 100∼120V, 320VA, 50/60Hz 228-34350-92 100∼120V, 320VA, 50/60Hz Power requirements 228-34350-38 220∼240V, 320VA, 50/60Hz Options for SCL-10AVP SCSI option Expansion Board, PC-4 A/D Board, PC-55N RS-232C/Optical Link Interface, PC-56N For communication with PC via SCSI interface. Provides 4 additional fiber optic ports. To acquire one detector analog signal. Max 2 boards can be installed. Serial communication port to Chromatopac via RS-232C cable or via Optical fiber cable. Requires a cable separately. 228-34359-91 228-23517-91 223-04202-91 223-02983-91 SHIMADZU CORPORATION. International Marketing Division 3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Cable Add.:SHIMADZU TOKYO Phone: 81(3)3219-5641 Fax. 81(3)3219-5710 SHIMADZU SCIENTIFIC INSTRUMENTS, INC. 7102 Riverwood Drive, Columbia, Maryland 21046, U.S.A. Phone: 1(410)381-1227 Fax. 1(410)381-1222 Toll Free: 1(800)477-1227 SHIMADZU DEUTSCHLAND GmbH Your International Resource for HPLC Validation Albert-Hahn-Strasse 6-10, D-47269 Duisburg, F.R. Germany Phone: 49(203)7687-0 Fax. 49(203)766625 SHIMADZU (ASIA PACIFIC) PTE LTD. 16 Science Park Drive #01-01 Singapore Science Park, Singapore 118227, Republic of Singapore Phone: 65-778 6280 Fax. 65-779 2935 SHIMADZU SCIENTIFIC INSTRUMENTS (OCEANIA) PTY. LTD. Units F, 10-16 South Street Rydalmere N.S.W. 2116, Australia Phone: 61(2)9684-4200 Fax. 61(2)9684-4055 SHIMADZU DO BRASIL COMERCIO LTDA. Rua Cenno Sbrighi, 25, Agua Branca, Sao Paulo, CEP 05036-010, BRAZIL Phone: (55)11-3611-1688 Fax. (55)11-3611-2209 SHIMADZU (HONG KONG) LIMITED Suite 1028 Ocean Center, Harbour City, Tsim Sha Tsui, Kowloon HONG KONG Phone: (852)2375-4979 Fax. (852)2199-7438 Overseas Offices and Productivity Istanbul, Beijing, Shanghai, Guangzhou, Shenyang, Chengdu, Moscow URL http://www.shimadzu.com Printed in Japan 3295-05304-30ATD The contents of this catalog are subject to change without notice.
Shimadzu HPLC Standard Operation Procedure Dr. Sana Mustafa Assistant Professor Depart. Of Chemistry FUUAST, Karachi. 2 Objective Demonstration of HPLC Instrument and Software Operation Perform Single Analysis. Instrument Specification 4 Shimadzu Model LC20A System Pump(A & B) 2 LC-10AT Detector SPD-20A Colum Oven CTO-20A Colum Shim-pack VP. We purchased a Shimadzu HPLC with PDA detector about 12 months ago running Class VP 5.02 software (recently upgraded to 5.03) under Windows 95. Unlike some reports I have read, we have found the hardware to be very reliable, easy to use and the results are reproducible. The Class VP software is a.
Class Vp Software
Specifications
SHIMADZU SCL-10A VP HPLC SYSTEM CONTROLLER w/ Manual & Class VP SOFTWARE PACKAGE - $2,499.00. Shimadzu SCL-10A VP HPLC SYSTEM CONTROLLER This sale is for a Shimadzu SCL-10A VP HPLC SYSTEM CONTROLLER University and Corporate POs accepted. Please message for details. Condition: Great working unit. Excellent working condition. Surplus from laboratory. Shimadzu Class Vp Software Manual is a software selection with 43 downloads. The most lightweight of them are Clear HTML Tags (sized at 253,339) and TimeTable Manager (sized at 389,770), while the largest one is Dragon Age II with 2,022,044,866 bytes. Save shimadzu software to get e-mail alerts and updates on your eBay Feed. Shimadzu SCL-10A VP HPLC SYSTEM CONTROLLER w/ Manual & Class VP SOFTWARE PACKAGE See more like this.
Shimadzu Class Vp Software Free
Used Shimadzu SCL-10AVP System Controller
Shimadzu Class Vp Software Download
System Controller for Shimadzu VP Series HPLC System (SCL-10A VP) Command all VP Series components centrally with Shimadzu’s SCL-10AVP System Controller. The SCL-10AVP conveniently links all VP Series modules via fiber optic interfacing for easy “plug-andplay” setup, and is backward compatible with previous Shimadzu systems. Single point control allows user-friendly operation from the controller’s easy-to-read, menu-driven display screens. For unmatched control capability, pair the SCL-10AVP with Shimadzu’s powerful CLASS-VP™ chromatography software. GLP/GMP compliance * Built-in validation support functions help you comply with GLP/GMP regulations. A record of each module’s operation is preserved and can be reviewed on-screen. Transfer and store methods * Save method parameters to the built-in 3.5” disk drive for reference and for secure transfer to other VP Series HPLC Systems. ROM version updates are downloaded from disk for easy upgradeability. User-friendly interface * Large, easy-to-read characters, icons and user-selectable display menus simplify system operation for novice and advanced users. * Flow rates, gradient programs, chromatograms, and wavelength scan data (from the SPD-10AVP and 10AVVP) are displayed on-screen for easy graphical parameter determination and setup Advanced operation * Function keys and detailed help information (with valid parameter ranges) streamline parameter setup and instrument operation. * Time programs are easily created for precise component control. * The graphical user interface rapidly creates and edits gradient curves for VP Series solvent delivery units (LC-10ADVP and 10ATVP). Simple mode for routine analyses * Operate your isocratic system with a simplified parameter setup. Enter pump flow rate, detector wavelength, column oven temperature and autoinjector batch schedule parameters. Advanced mode for full control * The SCL-10AVP’s advanced mode accesses full VP Series capability. All operational parameters are controlled by the SCL-10AVP. For autoinjector pretreatment programming, select either simple mode (Quick-pret) or full mode (Pret-prog). Custom display * For fast, easy operation, tailor the menu options to your requirements Advanced fiber optic communication * Each component of the LC-10AVP Series is connected to the system controller by fiber optic interface. This low noise, highspeed mode of data transmission enhances the reliability and sensitivity of the HPLC system. An optional SCSI interface allows multiple VP Series HPLC Systems to be linked. CLASS-VP™ workstation interface * Digital signals from VP Series detectors are rapidly transmitted from the SCL-10AVP to the CLASS-VP Chromatography Workstation by standard RS-232C interface. Analog signals from other manufacturers’ detectors can be converted to digital by the SCL-10AVP (option)